  • Data Logger
  • EL-GFX-2 Temperature and Relative Humidity Data Logger with Graphic LCD Screen

EL-GFX-2 Temperature and Relative Humidity Data Logger with Graphic LCD Screen

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail EL-GFX-2 Temperature And Relative Humidity Data Logger With Graphic LCD Screen

EL-GFX-2 Temperature and Relative Humidity Data Logger with Graphic LCD Screen • -30 to + 80° C and 0 to 100% RH measurement ranges • Logging rates between 10 seconds and 1 hour • Immediate, delayed, push-button or temperature/ RH triggered start mode • Graphic LCD shows real-time readings, graph and current status • Stores over 250, 000 readings • Calibration certificate available The EL-GFX-2 standalone USB data logger measures and stores over 250, 000 temperature and humidity readings over a -30 to + 80º C ( -22 to 176° F) and 0 to 100% RH range at a resolution of 0.1º C and 0.1% RH. Using the Windows control software ( available as a free download from www.easylogusb.com) , users can quickly set up the data logger and view downloaded data by connecting the device to the PC’ s USB port using the supplied cable. The data logger features a high-contrast graphic LCD and three-input buttons. This allows users to start, stop and restart the data logger using on-screen menus. This menu also provides real-time analysis of data either as a data summary ( showing highest & lowest readings and alarm conditions) or as a graph that updates as new data is added. Multiple data logging sessions can be stored on the device ready for upload to a PC at a later date. The data logger’ s robust design provides IP-67 waterproof protection and the two replaceable ½ AA batteries typically allow logging for up to four months. * This specifies the overall error in the logged readings, for relative humidity measurements between 20 and 80% RH. * * This specifies the overall error in the calculated dew point for relative humidity measurements between 40 and 100% RH at 25° C. * * * At temperatures below -5° C the LCD will exhibit slower response times. The LCD will be disabled at temperatures under -20° C and above 70° C. † At 25° C and 10 minute logging rate, with no alarm LEDs or sounder and minimal LCD use Informasi lebih lanjut hubungi kontak dibawah ini: Office : Jl.Radin Inten II No 61 B Duren Sawit Jakarta Timur Phone : 021-29563045 ( hunting) Hp : 08156141954 Fax : 021-29563052 Pin BB : 284152F7 Email : sales@ testingindonesia.com Website : www.testingindonesia.com
Tampilkan Lebih Banyak